The Airvo 2 is a compact nasal high flow system with an integrated flow generator, designed to deliver Optiflow NHF therapy across various care settings, ensuring patient comfort and effective therapy delivery.
1.1 Overview of the Airvo 2 System
The Airvo 2 is a compact nasal high flow (NHF) system with an integrated flow generator, designed to deliver Optiflow NHF therapy across various care settings. It operates at flow rates from 2 to 60 L/min, providing warmed and humidified respiratory gases to patients. The system includes a flow generator, humidifier, and patient interfaces, ensuring optimal comfort and therapy effectiveness. Its user-friendly design features a touch interface, multiple operating modes, and advanced sensors for precise temperature, flow, and oxygen monitoring, making it suitable for both hospital and home care environments.
1.2 Key Features and Benefits
The Airvo 2 offers a compact design with an integrated flow generator, delivering Optiflow NHF therapy across settings. It provides flow rates from 2 to 60 L/min, ensuring versatile care. Advanced sensors monitor temperature, flow, and oxygen levels, with self-checks for reliability. The user-friendly interface features touch controls and multiple operating modes, including hospital and home care settings. Customizable environment settings and 22 language options enhance usability, making it adaptable for diverse patient needs and global healthcare environments.
Safety Guidelines and Precautions
Ensure proper cleaning and disinfection between patients. Use only approved accessories to maintain performance and safety. Follow setup instructions carefully to avoid device malfunction or patient discomfort.
2.1 Essential Safety Information
Always follow the manufacturer’s guidelines for safe operation. Ensure proper setup and use only approved accessories to maintain performance and safety. Regularly clean and disinfect the device between patients to prevent contamination. The Airvo 2 must not be modified or altered in any way, as this could compromise safety. Only authorized personnel should adjust advanced settings. Use the device solely for its intended purpose, and adhere to all warnings and cautions to avoid alarms or therapy interruptions.
2.2 Contraindications and Warnings
- Use only as prescribed by a healthcare professional; improper use may cause serious injury.
- Avoid using non-approved accessories, as they may impair performance or safety.
- The device must be cleaned and disinfected between patients to prevent contamination.
- The maximum oxygen fraction should not exceed 95%, as indicated by the device’s alarm system.
- Sensors must not be tampered with, as this could lead to inaccurate readings or malfunctions.
- Always follow the user manual and manufacturer guidelines to ensure safe operation.
Technical Specifications
The Airvo 2 delivers a flow rate of 2-60 L/min, with integrated humidification and temperature control, ensuring precise oxygen delivery and comfortable therapy for patients across care settings.
3.1 Flow Rate and Oxygen Delivery
The Airvo 2 delivers a flow rate of 2 to 60 L/min, utilizing Optiflow NHF technology to provide precise oxygen delivery. The system allows for accurate control of oxygen fraction, ensuring consistent therapy. With its advanced design, the Airvo 2 optimizes oxygen delivery while minimizing consumption, making it adaptable for various clinical settings and patient requirements, ensuring effective and reliable respiratory support for both adult and pediatric patients in different care environments.
3.2 Humidification and Temperature Control
The Airvo 2 incorporates an advanced humidification system, delivering warmed and humidified respiratory gases for enhanced patient comfort. The system maintains a consistent temperature range, adjustable to suit individual patient needs, ensuring optimal gas delivery. The auto-fill water chamber simplifies setup, while the heated breathing tube prevents condensation, ensuring precise temperature control. This feature minimizes discomfort and irritation, promoting effective therapy and patient adherence to treatment protocols across various clinical settings.
3.4 Sensors and Alarms
The Airvo 2 features advanced sensors for temperature, flow, and oxygen levels, ensuring precise monitoring and accurate therapy delivery. These sensors are rigorously calibrated to meet strict criteria. The device performs regular self-checks, comparing sensor readings against expected values. Alarms are triggered for conditions like high oxygen levels (above 95%) or drops below set thresholds, ensuring patient safety and system reliability. Visual and audible alerts notify users of issues, enabling prompt interventions to maintain optimal therapy settings and patient care.
Setting Up the Airvo 2
Mount the Airvo 2 on a pole tray below patient head height. Unpack and connect components, including the water chamber and heated breathing tube, following manual instructions.
4.1 Unpacking and Initial Setup
Begin by carefully unpacking the Airvo 2 system and its accessories. Place the device on a stable surface or mount it on a pole tray below patient head height. Remove all protective packaging materials and ensure no damage occurred during shipping. Locate the power cord, water chamber, heated breathing tube, and other essential components. Refer to the manual for a detailed list of included items. Before proceeding, verify that all parts are accounted for and undamaged. This step ensures a smooth and safe setup process for optimal functionality.
4.2 Mounting and Connecting Components
Mount the Airvo 2 on a pole tray (900PT405) below patient head height for stability. Attach the water chamber and heated breathing tube to ensure proper functionality. Connect the oxygen inlet extension kit as per the instructions provided. Plug the power cord into the device and ensure all components are securely fitted. Proper mounting and connection are critical for safe operation and optimal performance. Refer to the manual for specific guidance on each connection point to avoid errors during setup.
4.3 Preparing the Water Chamber
Begin by removing the blue port caps from the water chamber using the tear tab. Fill the chamber with distilled water to the recommended level to prevent mineral buildup. Reattach the caps securely to avoid leaks. Connect the chamber to the Airvo 2 device, ensuring proper alignment for a snug fit. Once connected, power on the device to test the system. Check for any alarms or indicators to confirm the chamber is functioning correctly and the system is ready for use.
Operating the Airvo 2
Power on the device and ensure the water chamber is properly connected. Use the interface to adjust flow rates and oxygen levels, monitoring alarms for any system issues;
5.1 Turning On the Device
To power on the Airvo 2, press the On/Off button located on the front panel. The device will perform a self-test, and the “Ready for use” symbol will appear once initialization is complete. Ensure the water chamber and heated breathing tube are properly connected before use. The device defaults to hospital mode but can be switched to home care mode if required. Always refer to the user manual for detailed instructions and safety precautions before operating the device.
5.2 Adjusting Flow and Oxygen Settings
To adjust the flow rate, press and hold the On/Mute button to access settings. Use the Up and Down arrows to select the desired flow (2-60 L/min) and confirm with the Mode button. Oxygen levels are adjusted via an external flowmeter, typically ranging from 0-100%. The device will alarm if oxygen levels exceed safe limits, ensuring patient safety. Always monitor settings and adjust according to clinical guidelines to optimize therapy delivery and comfort.
5.3 Understanding the User Interface
The Airvo 2 features an intuitive user interface with clear symbols and buttons for easy navigation. The display shows real-time data, including flow rate, oxygen levels, and temperature. Use the Up and Down arrows to adjust settings, and the Mode button to confirm changes. The Mute button silences alarms temporarily. The interface also includes status indicators like “Ready for use” and alerts for system errors. Language settings can be customized, and advanced menus are accessible for clinical adjustments, ensuring user-friendly operation across care settings.
Operation Modes
The Airvo 2 operates in Hospital Mode for acute care and Home Care Mode for long-term use, with options to switch modes and customize settings for flexibility.
6.1 Hospital Mode Configuration
Hospital Mode on the Airvo 2 is designed for acute care settings, enabling precise control over flow rates, oxygen levels, and temperature. Clinicians can adjust settings to meet specific patient needs, with options to set minimum and maximum flow rates (10-60 L/min) and oxygen fractions (30-100%). The mode also allows customization of target dew-point temperatures (31°C, 34°C, or 37°C) for optimal humidification. Advanced settings ensure safe and effective therapy delivery in high-acuity environments, with alarms and self-checks to maintain performance and patient safety.
6.2 Home Care Mode Setup
Home Care Mode is designed for long-term or non-critical care, offering simplified settings for patient comfort. To configure, press and hold the Up and Down buttons for 3 seconds, then select “myAIRVO 2” using the Mode button. This mode limits adjustments to essential settings, ensuring ease of use. A separate myAIRVO 2 User Manual is required for detailed instructions. Note that switching modes resets the device, requiring reconfiguration of settings for home use, ensuring safety and effectiveness in non-hospital environments.
6.3 Switching Between Modes
To switch between Hospital and Home Care modes, press and hold the Up and Down buttons for 3 seconds. Use the Mode button to select the desired mode. The device will reset, requiring reconfiguration of settings. This ensures safety and effectiveness when transitioning between care environments. A separate manual is available for Home Care Mode configurations, providing detailed guidance for non-critical care settings and ensuring optimal therapy delivery in diverse situations.
Maintenance and Cleaning
Regular cleaning and disinfection are essential for maintaining the Airvo 2. Follow the Disinfection Kit Manual (900PT600) for detailed instructions to ensure optimal functionality and patient safety.
7.1 Daily Cleaning Procedures
Perform daily cleaning of the Airvo 2 to maintain hygiene and functionality. Wash the water chamber and tubing with mild detergent, rinse thoroughly, and allow to air dry. Disassemble and clean all reusable components as per the Disinfection Kit Manual (900PT600). Ensure all parts are dry before reassembly to prevent moisture buildup. Regular cleaning helps maintain optimal performance and ensures patient safety. Refer to the manual for detailed steps and guidelines.
7.2 Disinfection Guidelines
Disinfection of the Airvo 2 is essential for preventing contamination and ensuring patient safety. Use the Disinfection Kit (900PT600) as outlined in the manual. Follow strict disinfection protocols, especially when the device is used for multiple patients. Failure to disinfect properly may lead to impaired performance or safety risks. Always use approved disinfectants and adhere to the instructions provided. Regular disinfection maintains device integrity and ensures optimal therapy delivery.
7.3 Reusable vs. Single-Use Components
The Airvo 2 system includes both reusable and single-use components. Reusable parts, such as the HC360 water chamber, require proper cleaning and disinfection as per the manual. Single-use components, like the MR290 chamber and heated breathing tube, must be replaced after each patient to prevent contamination. Always follow the Disinfection Kit Manual (900PT600) for detailed instructions. Proper handling ensures patient safety and maintains device performance. Failure to comply may lead to compromised therapy or infection risks.
Troubleshooting Common Issues
The Airvo 2 monitors sensors and triggers alarms for issues like high/low oxygen levels or temperature deviations. Regular self-checks ensure proper function. Consult the manual or contact Fisher & Paykel Healthcare for unresolved malfunctions.
8.1 Identifying and Resolving Alarms
The Airvo 2 features advanced sensors that monitor temperature, flow, and oxygen levels, triggering alarms for deviations. Visual and auditory alerts indicate issues like high/low oxygen or temperature extremes. To resolve, check oxygen supply, ensure proper connections, and verify settings. For persistent alarms, consult the troubleshooting guide or reset the device. Refer to the manual for detailed fault codes and solutions. Contact Fisher & Paykel Healthcare for technical assistance if issues persist.
8.2 Managing Device Malfunctions
In case of malfunctions, power off the Airvo 2, then restart to reset. Check all connections and ensure proper setup. If issues persist, refer to the troubleshooting guide in the manual. For critical malfunctions, contact Fisher & Paykel Healthcare support. Regular maintenance and updates can prevent malfunctions. Always follow the technical manual’s instructions for repairs and servicing to ensure optimal performance and patient safety.
8.3 Resetting the Device
To reset the Airvo 2, press and hold the Up, Down, and Mute buttons simultaneously for 5 seconds. This action restarts the device and restores default settings. Note that resetting does not clear alarms or historical data but ensures the system reinitializes properly. Always refer to the technical manual for detailed instructions and precautions before performing a reset. This process is useful for resolving minor software issues or preparing the device for a new setup.
Advanced Settings and Customization
The Airvo 2 offers advanced customization options, enabling healthcare professionals to tailor settings to specific patient needs, enhancing therapy effectiveness and patient comfort.
9.1 Navigating Advanced Menus
To access advanced settings on the Airvo 2, press and hold the Up and Down buttons for 3 seconds. This unlocks the menu, allowing clinicians to adjust flow rates, oxygen levels, and environmental settings. Use the Up and Down buttons to navigate through options and the Mode button to confirm changes. Advanced menus enable customization of therapy parameters, ensuring tailored care for diverse patient needs and clinical environments, with options to set limits for flow, oxygen, and temperature for optimal therapy delivery.
9.2 Customizing Environmental Settings
Clinicians can customize environmental settings on the Airvo 2 to tailor therapy for specific care environments. Adjustments include setting minimum and maximum flow rates (10-60 L/min), oxygen levels (30-100%), and target dew-point temperatures (31-37°C). These settings ensure optimal therapy delivery across diverse clinical settings, from ICU to home care. Use the Up and Down buttons to modify parameters, and press the Mode button to confirm changes, ensuring personalized and effective patient care across various environments and patient needs.
9.3 Setting Target Dew-Point Temperature
The Airvo 2 allows clinicians to set the target dew-point temperature between 31°C, 34°C, and 37°C. This setting ensures optimal humidity and temperature for respiratory comfort. Higher temperatures, like 37°C, are often used for tracheostomized patients or those requiring higher humidity. Use the Up and Down buttons to select the desired temperature, then press the Mode button to confirm. This customization ensures tailored therapy for individual patient needs, enhancing comfort and effectiveness during treatment.
Environmental Customization
The Airvo 2 enables customization of environmental settings, allowing clinicians to adjust flow rates, oxygen fractions, and dew-point temperatures to suit various care environments and patient needs.
10.1 Adjusting Flow and Oxygen Limits
The Airvo 2 allows clinicians to set specific limits for flow rates and oxygen fractions, ensuring personalized therapy. Flow rates can be adjusted between 10-60 L/min in 5 L/min increments, while oxygen fractions range from 30-100%. The device alarms if measured oxygen exceeds the set maximum or drops below the minimum, enhancing safety. These settings can be customized to meet individual patient needs and clinical requirements, providing precise control over therapy parameters.
10.2 Setting Minimum and Maximum Parameters
The Airvo 2 allows clinicians to set minimum and maximum parameters for flow rates and oxygen fractions. Flow rates range from 10-60 L/min, and oxygen fractions from 30-100%. These settings ensure personalized therapy. The device alarms if values exceed limits, ensuring safety. Clinicians can adjust parameters for different care environments, optimizing therapy while maintaining comfort and safety. This customization enhances precise treatment efficacy across various clinical settings.
Patient Comfort and Therapy
The Airvo 2 prioritizes patient comfort by delivering Optiflow NHF therapy, ensuring proper interface fit to prevent leaks, and allowing continuous monitoring of patient response for effective therapy delivery.
11.1 Ensuring Proper Fit of Interfaces
Proper fit of interfaces is crucial for effective therapy and patient comfort. Select the appropriate size and type of nasal prongs or mask to ensure a secure, leak-free seal. Regularly inspect and adjust the interface to prevent discomfort or skin irritation. Refer to the Airvo 2 manual for guidance on fitting and securing interfaces for optimal therapy delivery and patient satisfaction.
11.2 Monitoring Patient Response
Monitoring patient response is essential for ensuring the effectiveness of therapy. Clinicians should regularly assess clinical signs such as breathing rate, oxygen saturation, and comfort levels. Patient feedback regarding comfort, nasal irritation, or dryness should be noted and addressed promptly. Adjustments to flow rates or interface fit may be necessary to optimize therapy outcomes. Regular checks ensure the patient is tolerating the treatment well and achieving the desired therapeutic benefits.
11.3 Promoting Adherence to Therapy
Promoting adherence to therapy involves ensuring patient comfort and understanding. Provide clear instructions and demonstrate proper use of the Airvo 2 system. Encourage patients to communicate any discomfort or challenges. Regular follow-ups and positive reinforcement can enhance motivation. Ensuring the device is used consistently in various settings, such as home or hospital, improves therapeutic outcomes. Addressing concerns promptly and involving caregivers can further support long-term adherence to prescribed therapy.
Resources and Support
Access comprehensive resources, including the Airvo 2 User Manual, instructional videos, and dedicated support from Fisher & Paykel Healthcare for troubleshooting and operational assistance.
12.1 Accessing the User Manual
The Airvo 2 User Manual is available for download as a PDF from the Fisher & Paykel Healthcare website. It provides detailed instructions for setup, operation, and troubleshooting, ensuring safe and effective use of the device. The manual is designed for healthcare professionals and includes comprehensive guides for both hospital and home care modes. Regularly updated, it serves as a primary resource for optimizing therapy delivery and maintaining device performance. Always refer to the latest version for the most accurate information.
12.2 Utilizing Video Guides and Tutorials
Video guides and tutorials for the Airvo 2 are available on platforms like YouTube and the Fisher & Paykel Healthcare website. These resources provide step-by-step instructions for setup, operation, and troubleshooting. Additionally, the Airvo 2 Simulator App allows users to practice operating the device virtually. These tools are designed to enhance user understanding and competence, ensuring safe and effective use of the system in both clinical and home care settings.
12.4 Contacting Fisher & Paykel Healthcare
For assistance with the Airvo 2, contact Fisher & Paykel Healthcare directly. Their official website provides contact details, regional offices, and support resources. Additionally, the Airvo 2 Simulator App is available for training, and their education website offers courses and guides. For further support, reach out to your local Fisher & Paykel representative or visit their website at https://www.fphcare.co.nz/education/.
The Airvo 2 is a cutting-edge nasal high flow system designed to enhance patient comfort and therapy outcomes. By following the guidelines in this manual, users can ensure safe and effective operation. Proper setup, maintenance, and adherence to safety protocols are crucial for optimal performance. For further assistance, refer to the provided resources, including the user manual, video guides, and Fisher & Paykel Healthcare support. This comprehensive guide empowers users to maximize the benefits of the Airvo 2 system.